DT – Series User’s Manual
MKTF-208 06/12
Preparing unit for shipment:
5. Disconnect the inlet, concentrate, pre-filter, and permeate plumbing.
6. Drain all water from the pre-filter cartridge housings by unscrewing the housings,
removing the pre-filter cartridges, and drain the water from the housings.
7. Disconnect the tubing from the connectors on the permeate and concentrate
inlets and outlets.
8. Fully open the concentrate valve.
9. Drain the flow meters.
10.Allow the system to drain for a minimum of eight hours or until the opened ports
quit dripping.
11.After draining is complete, reconnect all of the plumbing.